RV generator repair in Central Florida
Onan generator repair searches around Orlando are highest from June to September, the heart of hurricane season. A generator that sat unused since spring is the one that refuses to start when the power goes out.
Techs work wherever the RV is parked: campground, storage yard or home.

Generator problems
- Cranks, never fires
Old gasoline gums up a carburetor quickly in heat. Low oil or a low fuel level will also block a start.
- Starts, then dies
Often a fuel supply problem: clogged filter, varnished jets, or a tank below the generator's pickup.
- Surges or hunts
Engine speed rising and falling points to fuel or governor trouble.
- Runs, but no power inside
Before blaming the generator itself, look at its built-in breaker and at the transfer switch.
Generator repair costs
| Repair | Typical cost | Source |
|---|---|---|
| Generator diagnosis, before parts and labor | $137–450 | Camping World, “Mobile RV Repair Cost Guide”, July 2026 |
| Technician labor, per hour | $140–200 | hourly rates quoted in Camping World, “RV Furnace Repair Cost Guide”, October 2026 and in Micro-Air, “How much does it cost to replace an RV AC unit”, June 2026 |
Rough 2026 budget only — the tech sets the real price once they see the RV.
A fuel system cleaning is far cheaper than a replacement generator, so pay for the diagnosis first.
Figures checked November 2026.
Before calling
- Fuel above a quarter tankOn many motorhomes the generator pickup sits higher than the engine's, around the quarter mark, so the coach keeps driving while the generator starves.
- Oil levelLow-oil shutdown stops the generator within seconds. Check the dipstick on level ground.
- Tripped switchesThe generator has a breaker on its housing; the power center has a main. Check both.
- Monthly exerciseCummins Onan's guidance: exercise it every month for at least two hours with about half its rated load on.

In the generator bay
The tech checks fuel delivery, the carburetor or fuel injection, spark, the oil sensor and the control board, then tests output voltage and frequency under load.
Routine service — oil, filters, plugs — is part of the same visit. A carburetor full of varnish may be cleaned or swapped.
Generator questions
Should I store the generator with fuel stabilizer?
If it will sit for a month or more, stabilized fuel and a monthly run are the usual advice. Unused gasoline is the most common reason generators fail.
Can I run my generator during a hurricane?
Only in open air, well away from openings, and never in a garage or enclosed space. Carbon monoxide kills people every storm season.
Can a mobile tech service an Onan on site?
Yes. Most diagnosis and routine service happens in the generator bay. Major rebuilds may need the unit taken out.
Send your RV problem to a tech
A phone number is enough. A tech with time for the job calls you back.